Surprenant® A-D2® Military Grade
Radiation Cross-Linked Modified Flexible Fluoropolymer Wire
Insulation: Extruded Layer of Irradiation Cross-Linked Modified Flexible Fluoropolymer Conductor: Soft Annealed Tin Plated Copper (Various Strandings Available) Operating Temperature: 150°C Operating Voltage: 600 Volts Download pdf of this page |
|
ApplicationsThis irradiated flexible fluoropolymer insulated wire is formulated for high temperature applications where mechanical durability and flexibility are required. |
- Additional Requirements
Cable Specifications
Single conductor data shown below. Please contact our sales department for other configurations.
Part Number |
Conductor | Conductor Resistance @20ºC |
Nom. Diameter |
Weight | ||||||
Size | Stranding | Material | ||||||||
AWG | mm2 | Ω/kft | Ω/km | Inch | mm | lbs/kft | kg/km | |||
A-D2-2619TC-X | 26 | .15 | 19/38 | TC | 41.3 | 136 | .031 | .79 | 1.4 | 2.08 |
A-D2-2419TC-X | 24 | .24 | 19/36 | 26.2 | 86.0 | .036 | .91 | 2.0 | 2.98 | |
A-D2-24105TC-X | 24 | .24 | 105/44 | 28.2 | 92.5 | .037 | .94 | 2.1 | 3.12 | |
A-D2-2219TC-X | 22 | .38 | 19/34 | 16.2 | 53.2 | .042 | 1.07 | 2.8 | 4.17 | |
A-D2-2265TC-X | 22 | .38 | 65/40 | 18.8 | 61.7 | .043 | 1.09 | 2.9 | 4.32 | |
A-D2-2019TC-X | 20 | .62 | 19/32 | 9.88 | 32.4 | .051 | 1.3 | 4.4 | 6.55 | |
A-D2-20105TC-X | 20 | .62 | 105/40 | 11.7 | 38.4 | .053 | 1.34 | 4.3 | 6.40 | |
A-D2-1819TC-X | 18 | .96 | 19/30 | 6.23 | 20.4 | .061 | 1.55 | 6.7 | 9.97 | |
A-D2-18168TC-X | 18 | .96 | 168/40 | 7.14 | 23.4 | .064 | 1.63 | 6.8 | 10.1 | |
A-D2-1619TC-X | 16 | 1.23 | 19/29 | 4.81 | 15.8 | .068 | 1.73 | 8.5 | 12.7 | |
A-D2-16259TC-X | 16 | 1.23 | 259/40 | 4.53 | 14.9 | .079 | 2.01 | 10.2 | 15.2 | |
A-D2-14665TC-X | 14 | 1.94 | 665/42 | 2.96 | 9.71 | .099 | 2.51 | 16.5 | 24.6 | |
A-D2-12665TC-X | 12 | 3.08 | 665/40 | 1.89 | 6.20 | .121 | 3.07 | 24.8 | 36.9 | |
A-D2-10665TC-X | 10 | 4.74 | 665/38 | 1.12 | 3.67 | .157 | 3.99 | 42.2 | 62.8 | |
A-D2-08665TC-X | 8 | 8.61 | 665/36 | .714 | 2.34 | .195 | 4.95 | 66.3 | 98.6 | |
A-D2-061045TC-X | 6 | 13.6 | 1045/36 | .490 | 1.61 | .236 | 5.99 | 102 | 152 |
All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.
Additional Requirements
Blocking: 150 ±3°C For 24 Hours
Concentricity: 70% min.
Cross-Link Proof Test: 300 ±3°C
Flammability: VW-1
Insulation Elongation: 75% min.
Insulation Tensile: 3500 lbf/in2 min.
Insulation Resistance: 500 MEG-OHMS for 1000 ft. min.
Life Cycle: 200 ±3°C For 500 Hours
Low Temperature - Cold Bend: -65 ±3°C
Secant Modulas: 50,000 lbf/in2
Shrinkage: 150 ±3°C For 6 Hours
Smoke Test: 200 ±3°C (No Visible Smoke)
Thermal Shock: 150 ±3°C - .125 in. max.
Voltage Withstand Test: 2500 Volts (rms)
- Irradiated Flexible Fluoropolymer Insulated Wire
- Formulated for High Temperature Applications
- Mechanical Durablility and Flexibile Superiority