MIL-DTL-24640 /9-13, 25 & 26 Cable

Lightweight Low Smoke Wire Cable

Military Grade Cable Conductor: Manufactured to SAE AS81044/12
Jacket: Irradiation Cross-Linked Modified Low Smoke Polyolefin, Compounded without Halogens

Download pdf of this page
 

Applications

Electronic, communication and instrumentation: MIL-DTL-24640 Slant Sheets 9 thru 13, 25 & 26 unless noted, utilize insulated conductors manufactured to SAE AS81044/12. These constructions are either watertight (noted) or non-watertigght. The overall jacket is an irradiation cross-linked modified low smoke polyolefin that is compounded without halogens.

Cable Specifications


Cable Type No./
Size
Slant
Sheet
Military
PIN
Conductor Shield Product Description
AWG Stranding
2XS 2-30 9 -01UN thru
-08UN
22 19/34 Y 2,3,7,10,14,19,24 & 30 Shielded Pairs
Overall Jacket
2XSW 2-30 9 -09UN thru
-16UN
22 7/30 Y 2,3,7,10,14,19,24 & 30 Shielded Pairs, Watertight,
Overall Jacket
2XSO 3-30 9 -01UO thru
-06UO
22 19/34 Y 3,7,10,14,19 & 30 Shielded Pairs
Overall Shield & Jacket
2XSOW 3-30 9 -07UO thru
-12UO
22 7/30 Y 3,7,10,14,19 & 30 Shielded Pairs, Watertight,
Overall Shield & Jacket
MXSO 2-37 10 -01U0 thru
-04U0
16 19/29 Y 2,9,21 & 37 Conductors
Overall Shield & Jacket
MXSOW 2-37 10 -05U0 thru
-08U0
16 7/24 Y 2,9,21 & 37 Conductors, Watertight, 
Overall Shield & Jacket
3XS 7 11 -01UN 18 19/30 Y 7 Shielded Triads
Overall Jacket
3XSW 7 11 -02UN 18 7/26 Y 7 Shielded Triads, Watertight,
Overall Jacket
2XO 6-77 12 -01UO thru
-06UO
26 19/38 Y 6,18,24,42,60 & 77 Pairs
Overall Shield & Jacket
2XOW 6-77 12 -07UO thru
-12UO
26 7/34 Y 6,18,24,42,60 & 77 Pairs, Watertight,
Overall Shield & Jacket
2XSXO 4 13 -01UO 26 19/38 Y 4 Shielded Pairs
Overall Shield & Jacket
2XSXOW 4 13 -02UO 26 19/38 Y 4 Shielded Pairs, Watertight,
Overall Shield & Jacket
9XS 12 25 -01UO 12 37/28 Y 4 Pairs & 1 Conductor
Overall Shield & Jacket
10 -02UO 10 37/26 4 Pairs & 1 Conductor, using 81044/9 Components
Overall Shield & Jacket
8 -03UO 8 133/29 4 Pairs & 1 Conductor, using 81044/9 Components
Overall Shield & Jacket
5XO 3 26 -01UO 16 19/29 Y 5 Conductors
Overall Shield & Jacket
4 -02UO 14 19/27
6 -03UO 12 37/28

O in Part Number indicates that the cable has an optimized shield. The optimized shield is a single braid that is constructed to provide the same shielding performance as a double braid in the MIL-DTL-24643 specification, while saving weight and reducing the cable diameter. The optimized shield provides 60 db shielding from dc to 100 MHz.

All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.