MIL-DTL-24640 /1-8 Cable

Lightweight Low Smoke Wire Cable

Military Grade Cable Conductor: Manufactured to SAE AS81044/12
Jacket: Irradiation Cross-Linked Modified Low Smoke Polyolefin, Compounded without Halogens

Download pdf of this page
 

Applications

Electronic, communication and instrumentation: MIL-DTL-24640 Slant Sheets 1 thru 8 unless noted, utilize insulated conductors manufactured to SAE AS81044/12. These constructions are all QPL listed and are either watertight (noted) or non-watertight. The overall jacket is an irradiation cross-linked modified low smoke polyolefin that is compounded without halogens.

Cable Specifications


Cable Type No./
Size
Slant
Sheet
Military
PIN
Conductor Shield Product Description
AWG Stranding
DX 3 1 -01UN 16 19/29 N 2 Conductors, Overall Jacket
4 -02UN 14 19/27
DXWB 3 1 -03UN 16 7/24 N 2 Conductors, Watertight, Overall Jacket
4 -04UN 14 7/22
TX 3 2 -01UN 16 19/29 N 3 Conductors, Overall Jacket
4 -02UN 14 19/27
TXWB 3 2 -03UN 16 7/24 N 3 Conductors, Watertight, Overall Jacket
4 -04UN 14 7/22
FX 3 3 -01UN 16 19/29 N 4 Conductors, Overall Jacket
4 -02UN 14 19/27
FXWB 3 3 -03UN 16 7/24 N 4 Conductors, Watertight, Overall Jacket
4 -04UN 14 7/22
TTX 3 & 15 4 -01UN &
-02UN
20 19/32 N 3 & 15 Pairs, Overall Jacket
TTXWB 3 & 15 4 -03UN &
-04UN
20 7/28 N 3 & 15 Pairs, Watertight, Overall Jacket
TTXS 2 & 4 5 -01UN &
-02UN
20 19/32 Y 2 & 4 Shielded Pairs, Overall Jacket
TTXSW 2 & 4 5 -03UN &
-04UN
20 7/28 Y 2 & 4 Shielded Pairs, Watertight, Overall Jacket
TTXSO 2-10 5 -01UO thru
-04UO
20 19/32 Y 2,6,8 & 10 Shielded Pairs
Overall Shield and Jacket
TTXSOW 2-10 5 -05UO thru
-08UO
20 7/28 Y 2,6,8 & 10 Shielded Pairs, Watertight,
Overall Shield and Jacket
2XAO 2-40 6 -01U0 thru
-05UO
22 19/34 Y 2,7,10,18 & 40 Pairs
Overall Shield and Jacket
2XAOW 2-40 6 -06U0 thru
-10UO
22 7/30 Y 2,7,10,18 & 40 Pairs, Watertight,
Overall Shield and Jacket
1XMSO 7-70 7 -01U0 thru
-03UO
22 19/34 Y 7,16 & 70 Shielded Singles
Overall Shield & Jacket
1XMSOW 7-70 7 -04U0 thru
-06UO
22 7/30 Y 7,16 & 70 Shielded Singles, Watertight,
Overall Shield & Jacket
MXO 10 & 14 8 -01UO &
-02UO
20 19/32 Y 10 & 14 Conductors
Overall Shield & Jacket
MXOW 10 & 14 8 -03UO &
-04UO
20 7/28 Y 10 & 14 Conductors, Watertight,
Overall Shield & Jacket

O in Part Number indicates that the cable has an optimized shield. The optimized shield is a single braid that is constructed to provide the same shielding performance as a double braid in the MIL-DTL-24643 specification, while saving weight and reducing the cable diameter. The optimized shield provides 60 db shielding from dc to 100 MHz.

All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.