M55021 Cables

NEMA WC 55021 Shielded and Unshielded Military Wire Cable

Military Grade Cable Conductor: Various Platings and Strandings
Insulation: Various Insulation Types
Shield: Various Materials (Shielded and Unshielded)
Jacket: Various Materials (Shielded and Unshielded)

Download pdf of this page and how to specify a part number
 

Applications

The NEMA WC 55021 Specification is used to describe both shielded and unshielded cable constructions for internal wiring for electronic equipment. The specification allows the user a wide variety of construction choices. Circuit identification, conductor size, insulation type, number of conductors, shielding material and jacket compound may all be specified using the document. Single conductor, twisted pairs, triple, quad, quintuple and multi-conductor cables through 5 components are all included.

Marmon Aerospace and Defense® is able to provide a wide range of NEMA WC 55021 constructions. Although the website cannot list all the detailed testing and specification requirements contained in the complete NEMA WC 55021 document, we have summarized the major construction features of the specification and listed those that Marmon Aerospace & Defense® produces. Please refer to NEMA WC 55021 for complete performance details.

Cable Specifications

Table 1: Basic Wire Specifications

Symbol Basic Wire Specifications Insulation Type Temp Rating Voltage
L NEMA HP 5 (XLPE) TPC 125°C 600V
LL NEMA HP 5 (XLPE) TPC 125°C 1000V
LS NEMA HP 8 (XLPO) TPC 125°C 600V
LX NEMA HP 5 (XLPE) TPC 125°C 3000V
S NEMA HP 6 (SILICONE) TPC/SPC 150°C/200°C 600V
SS NEMA HP 6 (SILICONE) TPC/SPC 150°C/200°C 1000V
SSB NEMA HP 6 (SILICONE/GLASS) TPC/SPC 150°C/200°C 1000V
ZH NEMA HP 8 (ZH-POLYOLEFIN) TPC 125°C 600V
ZHDM NEMA HP 8 (ZH-POLYOLEFIN) TPC 125°C 600V
ZHDH NEMA HP 8 (ZH-POLYOLEFIN) TPC 125°C 600V
ZHS NEMA HP 6 (ZH-SILICONE) TPC/SPC 150°C/200°C 600V
ZHSS NEMA HP 6 (ZH-SILICONE) TPC/SPC 150°C/200°C 1000V
ZHX NEMA HP 8 (POLYOLEFIN) TPC 125°C 1000V

Table 2: Shield Descriptions

Letter Symbol
Type
Shield Material Maximum Temperature Limit for Shield
Material (Information Only)
U Unshielded ---
N Nickel Plated Copper 260°C
S Silver Plated Copper 200°C
T Tin Plated Copper 150°C

Table 3: Jacket Types

Letter Symbol
Type
Jacket Material
Type and Color
Maximum Temperature Limit for Jacket
Material (Information Only)
00 Unjacketed ---
01 Extruded White Polyvinyl Chloride (PVC) 90°C
02 Extruded Clear Polyamide 90°C
27 Extruded White Cross-Linked Polyolefin 105°C
28 Extruded White Cross-Linked Zero Halogen Polyolefin 105°C
29 Extruded White Silicone 200°C
30 Extruded White Zero Halogen Silicone 200°C

Recommended Shield and Jacket Types

Symbol Basic Wire Specifications Shield
Material
Jacket Material Temperature Rating Voltage Rating
Table 1 Table 1 Table 2 Table 3
L

LL

LX
NEMA HP5
(MIL-DTL-16878/14)
NEMA HP5
(MIL-DTL-16878/15)
NEMA HP5
(MIL-DTL-16878/16)
U
T
00
27
105°C 600V
1000V
3000V
ZHS

ZHSS
NEMA HP6

NEMA HP6
U

T
00

30
150°C 600V

1000V
ZH
ZHX
LS
NEMA HP8
NEMA HP8
NEMA HP8
U
T
00
28
125°C 600V
1000V
600V

All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.