MIL-DTL-24643/15-18, 20, 26 & 71-73.
Low Smoke Power Distribution Cables and Lighting with Circuit Integrity Wire Cable
Conductor: Watertight Silicone and Glass Braids Jacket: Irradiation Cross-Linked Low Smoke Polyolefin. /26 is a low smoke red silicone rubber. Download pdf of this page |
|
ApplicationsThese cables have insulated conductors manufactured with a combination of silicone and glass braids which provide circuit integrity in case of a catastrophic fire. All constructions are watertight with the exception of slant sheets 71 thru 73. The overall jacket is an irradiation cross-linked low smoke polyolefin for all slant sheets except 26 which is a low smoke red silicone rubber. The silicone rubber jacketed cables are armored with an aluminum braid to provide mechanical protection. |
Cable Specifications
Cable Type | Size | Slant Sheet |
Military PIN |
Conductor | Shield/ Armor |
Product Description | |||||||
AWG | Stranding | ||||||||||||
LSDSGU | 3-23 | 15 | -01UN thru -05UN |
16-7 | 7 | N | 2 conductors, overall XLPO jacket. Navy sizes 3 thru 23 are available |
||||||
LSTSGU | 3-23 | 16 | -01UN thru -05UN |
16-7 | 7 | N | 3 conductors, overall XLPO jacket. Navy sizes 3 thru 23 are available. |
||||||
LSFSGU | 3-23 | 17 | -01UN thru -04UN |
16-7 | 7 | N | 4 conductors, overall XLPO jacket. Navy sizes 3 thru 23 are available. |
||||||
LSMSCU | 7-91 | 18 | -01UN thru -10UN |
18 | 7 | N | 7,10,14,19,24,30,37,44,61 & 91 conductors, overall XLPO jacket. | ||||||
LSMSCS* | 7-91 | 18 | -01UD thru -10UD |
18 | 7 | Shield | 7,10,14,19,24,30,37,44,61 & 91 conductors, overall double shield, XLPO jacket | ||||||
LS7SGU |
|
20 |
|
|
7 | N | 7 conductors, overall XLPO jacket | ||||||
LSDPS | 3-14 | 26 | -01AN thru -05AN |
16-9 | 7 | Armor | 2 conductors, overall silicone jacket. | ||||||
LSTPS | 3-30 | 26 | -06AN thru -12AN |
16-9 | 7 | Armor | 3 conductors, overall silicone jacket. Navy sizes 3 thru 30 are available |
||||||
LSFPS | 14 | 26 | -13AN | 9 | 7 | Armor | 4 conductors, overall silicone jacket. | ||||||
LS7PS | 6 & 14 | 26 | -14AN & -15AN | 12 & 9 | 7 | Armor | 7 conductors, overall silicone jacket. | ||||||
LSSCF | 3 thru 400 | 71 | -01UN thru -15UN |
16 thru 400 MCM | Various | N | 1 conductor, overall XLPO jacket. | ||||||
LSFCF | 42 | 72 | -01UO | 16 & 4 | Various | Shield | 4 conductors of 4AWG & 4 conductors of 16AWG, overall shield and XLPO jacket | ||||||
LSTCF | 200 | 73 | -01UN | 4/0 | 550/24 | N | 3 Conductors, Overall XLPO Jacket |
S at the end of the part number indicates that the cable has a double overall shield. The shields are constructed to provide 60 db shielding from dc to 100 MHz.
All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.